Posts
Using command line NVMe-oF DEMO to test off-load NVMe-oF target performance
/in Use Cases /by adminFrom the package of us, there are few demo utils to create a single pooled storage to demonstrate storage features and performance. Through the way, you can quick preview your favorite features in minutes.
For NVMe-oF target, you may run the following command to start:
/opt/flexsds/bin/flexsds -d nvmf spool 3 nvme://0000:04:00.0 nvme://0000:05:00.0 nvme://0000:05:00.0
outputs are:
found 1 ib devices
device0: mlx5_0, uverbs0, /sys/class/infiniband_verbs/uverbs0, /sys/class/infiniband/mlx5_0
copies: 2
create name space: nqn.2016-12.com.flexsds:all-flash-pool.volume0…done.
NVMe over Fabric service is started.
Configure NVMe-oF device with Multipath
/in Use Cases /by adminRequirements:
Linux Kernel 4.8 and newer.
Package: multipath, nvme-cli
Use the ways to install them:
#yum install device-mapper-multipath nvme-cli
Read more
Using Linux nvme-cli to connect to the FlexSDS’s NVMe-oF targets
/in Use Cases /by adminRequirements
To using Linux NVMe over Fabrics client, need Linux with kernel 4.08 and above.
Install the nvme-cli package on the client machine:
#yum install nvme-cli
or on Debian:
#apt-get install nvme-cli
Startup Kernel Module
#modprobe nvme-rdma
Discover NVMe-oF subsystems
nvme discover -t rdma -a 192.168.80.101 -s 4420
Discovery Log Number of Records 1, Generation counter 1 =====Discovery Log Entry 0====== trtype: rdma adrfam: ipv4 subtype: nvme subsystem treq: not specified portid: 1 trsvcid: 4420 subnqn:nqn.2016-12.com.flexsds:all-flash-pool.test_vol0 traddr: 192.168.80.101 rdma_prtype: not specified rdma_qptype: connected rdma_cms: rdma-cm rdma_pkey: 0x0000
Connect to NVMe-oF subsystems
nvme connect -t rdma -n nqn.2016-12.com.flexsds:all-flash-pool.test_vol0 -a 192.168.80.101 -s 4420
List nvme device info:
#nvme list
Node SN Model Namespace Usage Format FW Rev ---------------- -------------------- ---------------------------------------- --------- -------------------------- ---------------- -------- /dev/nvme0n1 FlexSDS Controller 1000 GB / 1000 GB 512 B + 0 B A34CCD834CD3544
Disconnect NVMe-oF subsystems
In order to disconnect from the target run the nvme disconnect command: